Unknown Interfaces
This concerns the appearance of interfaces flagged as "unknown" when looking at the device home page or when browsing through the "Managing Nodes" component on the web console. FYI - we are running...
View ArticleA Challenge: CPU Usage Alerts for a Single CPU/vCPU
I had a team approach me a few days ago and ask for a pretty wild request. They wanted to know when a single CPU exceeded the pre-defined CPU_Crit threshold (a custom property that we use) or the...
View ArticleHP Proliant Hard Drive Status MIB,OID Proliant DL 380 Gen 8
I have the MIB for monitoring the status of a hard drive for older HP servers - 1.3.6.1.4.1.232.3.2.5.1.1.6 - cpqDaPhyDrvStatus. This does not work with Proliant DL 380 Gen 8's. OID is not supported....
View ArticleCheckpoint Firewall shows up as an autonomous AP?
Does anybody know why NPM 11.0 thinks a Checkpoint firewall is an autonomous access point?
View Articlecan i put orion and the SQL on the same UCS server
Hey all, Brand spankin new Orion Admin here. I have read the docs on the admin guide and the best practices. But before I deployed this beast I wanted to verify my architecture. I know the guide...
View ArticleSolarwinds reporting wrong status for the VM
Server is up and running but Solar winds is reporting as server down, performed the SNMP test , test is failed .what are the steps need to follow to resolve this issue?
View ArticleFirewall reports
Hi, I'm trying to create a couple of reports on Firewall usage / security. These are running on Cisco ASAs. Report 1 - Firewall Security Report:Top 10 IncidentsNotable eventsTop 10 usersTop 10 rule...
View Articleproblem in SolarWinds Alerting Engine
I installed SolarWinds Orion on yesterday and everything was ok till today when i wanted to add some nodes and got report from charts.my orion web console didnt work and i got this error :then i...
View Articleproblem with the advanced Alert Manager
Hey People,i set an alarm to overwatch our Trunk Ports from cisco network devices and also create the UDNP for this. But if i want to create an alert this all fails.Also i can´t select the "status is...
View ArticleIn and Out Errors and Discards for sub-interfaces
Can we see on the Interface details page statistics for the resource “In/Out Errors and Discards” on sub-interfaces? For example, the G0/0.100 and g0/0.200 interfaces will not show any data but if I...
View ArticleCreate Cisco licensing report (show license)
Hi, I'm looking for a way to create a licensing report for all of our ASAs. Same as if I'd run 'show license' on each one of them. Is there anyone here that knows an easy way to provide this type of...
View ArticleMultiple Ping per Interval Feature Request
We are monitoring some cellular devices with low data plans due to minimal real data requirements.As a result, we can't be pinging these boxes every 30 seconds to keep the path alive. In NPM, we need...
View ArticleHow to edit the Policy Violations resource which can be added to node details
I wanted to add a policy violations resource to my node details page....I managed to but it is pre populated with info from polic reports I am not interested in. How can I select which policy I want...
View ArticleHardware Health Misreporting Temps on Cisco 3850
Just noticed that NPM is misreporting temperatures on our new Cisco 3850s. Any idea why this is occurring? The older 3750s are reporting fine. We are on NPM 10.6.1. From the switch itself...Switch 1...
View Articlehow do I create custom views?
I would like to create a custom view for a vlan on 2 Cisco routers that our InfoSec team is interested in seeing utilization stats. If I look at the vlan individually per device, it gives me the...
View ArticleCertain HTTP web pages do not refresh in ether IE 11 or FireFox. (NPM 10.7)
Im working on getting several local and state level web pages (specifically the NWS and a Local weather site) to run on a Loop for my NOC.This way they can monitor storms as well as potential lightning...
View ArticleURL variables in alerts
Where do the URL variables (Acknowledge URL, AlertDetailURL) get the hostname/FQDN from? The variables and alerts are being populated as http://NETBIOSNAME:80/blah and we want them to go as...
View ArticleHealth Monitoring
Hardware Health monitoring is turned on and is used to monitor power supplies, fans, and temperature on several nodes in the network. When an warning or critical condition is triggered I would expect...
View ArticlePDF Report Dimensions
Hi Everyone, I am running weekly reports and I was asked why the PDF is created with such strange dimensions. The "actual size", according to Acrobat Reader, is 8.3" x 11.7". If a user has changed...
View ArticleCreating Custom Poller Reports
All, I have several interface utilization reports running at regular intervals that I set up through the web-based reporting tool and they work great, and we're all happy - I just "Add Content" and...
View Article